Calculate the Model Response (GMS3MCALCF GX)

Use this GX to calculate the gravity or magnetic response of a 3D model.

Forward Calculation Options

Number of Taylor Series Terms

This is the number of terms in the Taylor series calculation. It must be an odd number, greater than or equal to 3. The default is 5.

Application Notes

GMS3MCALCF is the multi layer forward calculation component of GM-SYS 3D. It works by repeatedly calling GMS3CALCF.GX for the individual layers (or sub-layers in the case of Density/Depth table layers.) If called by GMS3GRAVF.GX, it calculates gravity. If called by GMS3MAGF.GX, it calculates magnetics.