Gradients to Total Magnetic Intensity
Use the 2D Filtering > Gradients to Total Magnetic Intensity menu option (geogxnet.dll(Geosoft.GX.FFT2D.GradientsToTMI;Run)*) to calculate the total magnetic intensity grid, given the coinciding X & Y horizontal derivatives of the magnetic field.
Gradients to Total Magnetic Intensity dialog options
|
Select the name of the input X gradient grid. Script Parameter: GRADIENTS_TO_TMI.XGRADIENT |
|
Select the name of the coinciding input Y gradient grid. Script Parameter: GRADIENTS_TO_TMI. YGRADIENT |
|
Specify the name of the output total magnetic intensity grid calculated from the X, Y gradient grids. Script Parameter: GRADIENTS_TO_TMI.OUTPUT |
Save intermediate grids |
Select to save the interim transform grids (optional). If you run this tool a subsequent time when the interim grids are in the working directory, they will be used rather than transforming the input grids again. Script Parameter: GRADIENTS_TO_TMI.SAVE_INTERMEDIATE_GRIDS |
[More] |
|
Expansion |
|
Expansion method |
Select the type of grid expansion. The options are:
Script Parameter: GRADIENTS_TO_TMI.EXPANSION_METHOD |
% expansion |
Specify the percent grid expansion (Default - 15). First the number of cells is augmented by the specified % expansion. Then it is further augmented to the next Winograd expansion number. Script Parameter: GRADIENTS_TO_TMI.PERCENT_EXPANSION |
Fill |
|
Fill method |
Select the grid fill method. The options are:
Script Parameter: GRADIENTS_TO_TMI.FILL_METHOD |
Roll-off distance |
Specify the number of cells beyond the valid area at which to roll-off to zero. Default: Circular continuity is maintained between the opposite edges of the grid, and the data is not rolled off to zero. Script Parameter: GRADIENTS_TO_TMI.ROLLOFF_DISTANCE |
Global amplitude limit |
Specify an amplitude limit. High amplitude anomalies can cause problems in FFT filtering. This option starts attenuating anomalies that exceed half the specified limit and caps them at this limit. Script Parameter: GRADIENTS_TO_TMI.GLOBAL_AMPLITUDE_LIMIT |
Edge amplitude limit |
Specify an edge amplitude limit. High amplitude anomalies on the edges of the valid area can produce oscillations in the extrapolated areas. Limit anomalies along the edges of the grids to this value. Script Parameter: GRADIENTS_TO_TMI.EDGE_AMPLITUDE_LIMIT |
Application Notes

*The GX tool will search in the "...\Geosoft\Desktop Applications \gx" folder. The GX.Net tools, however, are embedded in the geogxnet.dll located in the "...\Geosoft\Desktop Applications \bin" folder. If running this GX interactively, bypassing the menu, first change the folder to point to the "bin" folder, then supply the GX.Net tool in the specified format.
References
- C. D. Hardwick (Formerly National Research Council of Canada), "Two Methods of Gradient-Enhanced Gridding – A Discussion", Technical Paper (2004).
Got a question? Visit the Seequent forums or Seequent support
© 2023 Seequent, The Bentley Subsurface Company
Privacy | Terms of Use