Use the Specify Correction Parameters 1 dialog option (RPSCORR GX) to correct airborne radiometric data for the effects of spectral overlap (STRIPPING) and height attenuation. It also converts potassium, thorium and uranium data to apparent radioelement concentrations.
Specify Correction Parameters 1 dialog options
STRIPPING RATIOS: |
- - alpha (Default is 0.24) - - beta (Default is 0.37) - - gamma (Default is 0.70) - - a (Default is 0.05) - - b Default is 0.0) - - c (Default is 0.0) |
NOMINAL SURVEY ALTITUDE (metres) |
Specify the nominal survey altitude in metres (Default is 120). |
Specify Correction Parameters 2 dialog options
HEIGHT ATTENUATION COEFF: (per metre at STP): |
Total Count (Default is –0.0070) Potassium (Default is –0.0088) Uranium (Default is –0.0082) Thorium (Default is –0.0070) |
BROAD SOURCE SENSITIVITIES: |
Total Count (uR/hr) (Default is 23) Potassium (cps/% K) (Default is 75) Uranium (cps /ppm eU) (Default is 7.5) Thorium (cps /ppm eTH) (Default is 4.5) |
Application Notes
The radiometric data move from LEVL to CORR as noted by channel names. The GX applies stripping and height attenuation corrections, and converts previously levelled data to apparent Radioelement concentrations. To correct your database, complete the fields in the Specify Corrections Parameters dialog box (stripping, nominal survey altitude and broad source sensitivities) or accept the defaults as displayed. Select OK. You then see a progress bar indicating that the system is correcting the data.
When the GX finishes, we suggest you compare the raw, filtered (FILT), levelled (LEVL) and corrected (CORR) channels in the profile window.
Channels and Parameters
ULEVL |
Input U Channel Name |
KLEVL |
Input K Channel Name |
THLEVL |
Input TH Channel Name |
TCLEVL |
Input TC Channel Name |
|
|
UCORR |
Output U Channel Name |
KCORR |
Output K Channel Name |
THCORR |
Output TH Channel Name |
TCCORR |
Output TC Channel Name |
TCEXPOSURE |
Output TC Ground Level Exposure Channel Name |
RALTSTP |
Equivalent Height at STP channel |
|
|
ALPHA |
ALPHA Stripping Ratio |
BETA |
BETA Stripping Ratio |
GAMMA |
GAMMA Stripping Ratio |
ASTRIP |
A Stripping Ratio |
BSTRIP |
B Stripping Ratio |
GSTRIP |
G Stripping Ratio |
NOMALT |
Nominal survey altitude [metres] |
UATTEN |
Height Attenuation Coefficient for U |
KATTEN |
Height Attenuation Coefficient for K |
THATTEN |
Height Attenuation Coefficient for TH |
TCATTEN |
Height Attenuation Coefficient for TC |
USENS |
Broad Source Sensitivity for U |
KSENS |
Broad Source Sensitivity for K |
THSENS |
Broad Source Sensitivity for TH |