DSWP (Swap the contents of two buffers)
The DSWP command swaps the contents of two X, Y or Z data buffers.
Command Syntax:
Command Parameters:
xyz,xyz |
The data buffers to be swapped, specified as single letters 'x', 'y', or 'z'. |
|
If only one buffer is specified, then whichever of the X or Y buffers spanning the greatest range is placed in the specified buffer. This allows you to simply specify DSWP X in order to place the ordinate with the greatest range in the X buffer. |
Example:
WIND 1,2,15,22,23 /define a data window
WDEF 0,48000,1500,50000 /define window coordinates
DOPN mag,2 /open MAG.XYZ to read second Z
DXYZ L100 /read Line 100 into buffers
DSWP Z,Y /swap Z and Y buffer
LINA 0 /plot buffer as world coordinates
This control file will draw a scaled profile of the data in the second column of Line 100 in data file MAG.XYZ.
See Also:
Got a question? Visit the Seequent forums or Seequent support
© 2024 Seequent, The Bentley Subsurface Company