Configure RPS Data
Use the Configure option (RPSCNFIG GX) to carry out channel configuration setups for airborne radiometric data.
Define Raw Data Channels dialog options
RADIOMETRIC COUNTS (cps) |
Select the following channels from your current RPS database.
|
ALTIMETER |
|
Define Output Data Channels dialog options
CORRECTED DATA |
Specify the following output channels.
|
RATIOS |
|
OTHERS |
Ground Level Exposure (uR/h) STP Corrected Altimeter (metres) |
Application Notes
WARNING: You must be extremely careful when you set up channels. If you re-use a channel name accidentally, for instance, your processing will not be correct. We recommend that you check your results after each step to make sure that your channel names (as well as your processing values) are correct.
To configure your database, enter the deadtime and input channels in the Define Raw Data Channels dialog. Use the drop-down lists to select from existing channels in your database. Channel names are self-explanatory, for example, select TC_raw for the Total Count field and BALTRAW for the Barometric Altimeter channel. When you are finished, click OK.
The system displays an Define Output Data Channels dialog. Repeat the above procedure for output channels. In the previous dialog, you may have noticed that the drop-down lists displayed a list of all database channels. Now you should see that the drop-down list displays a predefined list of output channels. Although you are free to change the channel names, we strongly recommend you use the predefined names. When you are finished, click OK. The Configure dialog runs and defines all channels.
Channels and Parameters
URAW |
RAW U Channel Name |
KRAW |
RAW K Channel Name |
THRAW |
RAW TH Channel Name |
TCRAW |
RAW TCount Channel Name |
COSRAW |
RAW COSmic Channel Name |
BALTRAW |
RAW BALT Channel Name |
RALTRAW |
RAW RALT Channel Name |
|
|
UFILT |
Filtered U Channel Name |
KFILT |
Filtered K Channel Name |
THFILT |
Filtered TH Channel Name |
TCFILT |
Filtered TC Channel Name |
COSFILT |
Filtered COS Channel Name |
UPUFILT |
Filtered UP U Channel Name |
|
|
ULEVL |
Leveled U Channel Name |
KLEVL |
Leveled K Channel Name |
THLEVL |
Leveled TH Channel Name |
TCLEVL |
Leveled TC Channel Name |
|
|
UCORR |
Corrected U Channel Name |
KCORR |
Corrected K Channel Name |
THCORR |
Corrected TH Channel Name |
|
|
TCEXPOSURE |
Ground Level Exposure Rate |
UTHRAT |
U/TH Concentration Ratio |
UKRAT |
U/K Concentration Ratio |
THKRAT |
TH/K Concentration Ratio |
RALTSTP |
STP RALT Channel Name |
|
|
DEADTIME |
Equipment Deadtime |
CTEMP |
Temperature channel |
URADREF |
U Radon bgnd reference channel |
KRADREF |
K Radon bgnd reference channel |
THRADREF |
TH Radon bgnd reference channel |
TCRADREF |
TC Radon bgnd reference channel |
UPURADREF |
UP U Radon bgnd reference channel |
Got a question? Visit the Seequent forums or Seequent support
© 2024 Seequent, The Bentley Subsurface Company