RPS - Background

Use the Specify Aircraft Background & Cosmic Stripping Values dialog (RPSLEVL1 GX) to create background-corrected airborne radiometric data.

Specify Aircraft Background & Cosmic Stripping Values dialog options

Aircraft Background Values
(cps)

Select the aircraft background values (cps).
 

Total Count

 

Potassium

 

Uranium

 

Thorium

 

Upward U

Cosmic Stripping Ratios
(cps / cosmic cps)

Specify the cosmic stripping ratios (cps/cosmic cps)
 

Total Count

 

Potassium

 

Uranium

 

Thorium

 

Upward U

Select Radon Background Leveling Method dialog options

Choose Radon Background method from list

Select the radon background method from the drop-down list (Upward, Backgnd_Table or Overwater).

Additional Script Parameters

Script Parameter: RPSLEVL.UFILT

Input U Channel Name

Script Parameter: RPSLEVL.KFILT

Input K Channel Name

Script Parameter: RPSLEVL.THFILT

Input TH Channel Name

Script Parameter: RPSLEVL.TCFILT

Input TC Channel Name

Script Parameter: RPSLEVL.COSFILT

Input COSmic Channel Name

Script Parameter: RPSLEVL.ULEVL

Output U Channel Name

Script Parameter: RPSLEVL.KLEVL

Output K Channel Name

Script Parameter: RPSLEVL.THLEVL

Output TH Channel Name

Script Parameter: RPSLEVL.TCLEVL

Output TC Channel Name

Script Parameter: RPSLEVL.UCOSSTRIP

Ratio for U

Script Parameter: RPSLEVL.KCOSSTRIP

Ratio for K

Script Parameter: RPSLEVL.THCOSSTRIP

Ratio for TH

Script Parameter: RPSLEVL.TCCOSSTRIP

Ratio for TC

Script Parameter: RPSLEVL.UUCOSSTRIP

Ratio for Upward Uranium

Script Parameter: RPSLEVL.UAIRBACK

Background for U

Script Parameter: RPSLEVL.KAIRBACK

Background for K

Script Parameter: RPSLEVL.THAIRBACK

Background for TH

Script Parameter: RPSLEVL.TCAIRBACK

Background for TC

Script Parameter: RPSLEVL.UUAIRBACK

Background for Upward Uranium

 

 

Radon levelling reference channels

 

Script Parameter: RPSLEVL.URADREF

Uranium radon reference channel name

Script Parameter: RPSLEVL.KRADREF

Potassium radon reference channel name

Script Parameter: RPSLEVL.THRADREF

Thorium radon reference channel name

Script Parameter: RPSLEVL.TCRADREF

Total Count radon reference channel name

Script Parameter: RPSLEVL.UPURADREF

UP Uranium radon reference channel name

 

 

User input parameters for Radon levelling

Upward-looking method

UPA1, UPA2, UPAU, UPAT, UPAK and UPAI

Alpha values

UPBU, UPBT, UPBK and UPBI

Beta values

 

 

Radon levelling

Parameters for Overwater 2 table-based levelling

Script Parameter: RPSLEVL.RADBACK

Background picks lookup table file name

Script Parameter: RPSLEVL.RADREF

Radon Reference dummy channel. This method works on a flight of selected data. The data can be broken up into survey lines, as the table based method will take its entries and interpolate across lines from the first index value to the last.

 

Water Background levelling

Parameters for WaterBack levelling

Script Parameter: RPSLEVL.RADREF

Radon Reference dummy channel

 

Script Parameter: RPSLEVL.WBSWAV

Low pass Filter short wavelength cut-off value

Application Notes

The RPS Background option first corrects data for cosmic and aircraft background radiation. It then corrects data for atmospheric radon background radiation using one of several methods (Upward-looking crystals, Overwater2, or WaterBack methods).

The dialog works on pre-processed channels (denoted by FILT) and creates background-removed channels (denoted by LEVL). Note that in the current implementation these channel names are hardcoded. This streamlines the data input process.

The Background dialog runs three processes -- aircraft corrections, cosmic corrections and radon background corrections. There are three methods for applying radon corrections, including a channel-based method (upward-looking uranium), a table-based method (Overwater2), and an interactive highlighting method (WaterBack).

To level your database, you must complete multiple dialogs. The first of these is for aircraft background and stripping corrections and the second is for selecting a radon levelling method. Depending on the method you select, the system displays either two more or one more dialog.

Aircraft background and stripping values are normally supplied by your survey contractor. When you see this screen, you can either enter new values or accept the defaults as displayed. Click OK.

Next choose a method, for example, Upward and click OK. You see another dialog containing instrument-dependent proportionality factors and experimental constants. Enter the values for your survey or enter zeros and press OK.

The next dialog requires that you enter a name corresponding to the channel configured for upward-looking uranium data. Click OK. When Processing is complete, compare the raw, filtered (FILT) and levelled (LEVL) channels in the profile window.

Additional Notes

You may have noticed that the dialog in which you entered the name of the upward-looking channel also provided fields for levelling interim channels (UTEMP, etc).

The default filtering settings are designed to eliminate any remaining high frequency noise in the interim channel so that data are levelled as smoothly as possible.

To evaluate how these filters will affect levelling of datasets in the real world, you may want to experiment by changing the low pass value. A 200 point filter (for 1 second data) is recommended as a starting point - the data should be stored as a single line for the entire flight in order to use these long filters.

This method works on a line of data - therefore, if you want to process your data by flight (recommended), then you must store your flights of data as single lines until all processing is done. You can then break up the flight into survey lines.