Import IP Data from Interpex 12X Format File
Use the IPIMP1RESIX GX to import data from a single Interpex I2X format file to a specified line.
Import Interpex I2X format file dialog options
File to import
|
The Interpex I2x format file to import. The file must already exist.
Script Parameter: IP.I2X_FILE
|
Import to Line
|
Select the line to import the data to. The line may already exist (in the list), or you may specify a new name. The line name must be a valid Geosoft format line name, such as "L1000".
Script Parameter: IP.I2X_LINE
|
Resistivity (Data) Channel
|
Apparent resistivity from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_RES_IMAGE_MODEL
|
IP (Data) Channel
|
Apparent chargeability from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_IP_IMAGE_MODEL
|
Image Model Resistivity Channel
|
Synthetic resistivity data from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_RES_IMAGE_SYNTH
|
Image Model IP Channel
|
Synthetic chargeability from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_IP_IMAGE_SYNTH
|
Synthetic Resistivity Channel
|
Apparent resistivity synthesized from the polygon model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_RES_POLY
|
Synthetic IP Channel
|
Apparent chargeability synthesized from the polygon model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_IP_POLY
|
Resistivity (Polygon) Channel
|
Apparent resistivity from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_RES_IMAGE_MODEL
|
IP (Polygon) Channel
|
Apparent chargeability from image model channel for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_IP_IMAGE_MODEL
|
Zonge Resistivity Channel
|
Zonge synthetic apparent resistivity for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_RES_ZONGE
|
Zonge IP Channel
|
Zonge synthetic chargeability for import. Select one from the list, or leave blank and none will be imported.
Script Parameter: IP.I2X_IP_ZONGE
|
Import Mode
|
If REPLACE mode is selected, any data previously residing in the specified line (if it already exists) is lost. If the MERGE mode is selected, values in the imported channel will first be set to dummies, then values in the rows with matching Tx1 and "N" positions will be updated with values from the I2X file.
Script Parameter: IP.I2X_IMPMODE "R" : replace, "M": merge.
|
Application Notes
The IPIMP1RESIX GX is used to import a single line of data into the current database from an Interpex I2X format file. Up to 5 data sets may be imported, each with resistivity and IP data: the measured data, the image model values, data synthesised using the image model, and polygon data, calculated using user-created polygon models, and Zonge data.