Grid 1VD Data
Use the Grid 1VD Data option (UXGDRGRD GX) to grid 1st vertical derivative data (GRD) using the minimum curvature gridding method.
Grid 1VD Data dialog options
1VD channel to grid | Magnetic data channel to grid Script Parameter: UXGDRGRD.CHAN |
Output 1VD grid | Output grid file name (*.grd) Script Parameter: UXGDRGRD.GRID |
Grid cell size | Specify grid cell size Script Parameter: UXGDRGRD.CS |
Xmin,Ymin, | X and Y minimum and maximum coordinates. This defines the area on which to define the grid. You MUST enter all 3 commas if you enter ANY of these four values. The default produces a grid to the limits of the data. Entering a range of ,0,0,0 will cause the grid to cover the maximum limits of the data plus the blanking distance. For example, to produce a grid between 1000 and 10000 in X, and 500 and 5000 in Y, enter: 1000,500,10000,5000. Script Parameter: UXGDRGRD.XY |
Low-pass desampling | Low-pass filtering can be applied to a multiple of the grid cell size. Filtering should be considered if the data has uneven sampling and the cell size is less than about half the largest sample interval. For example, if the cell size is 50 metres and the largest nominal sampling is 200 metres, specify a desampling factor of 4. The default is 1. Script Parameter: UXGDRGRD.DSF |
Blanking distance | Areas of the grid beyond the blanking distance of valid data points will be dummied out. The blanking distance should be greater than the nominal sample interval. The default is 8 times the desampling factor times the the cell size. Script Parameter: UXGDRGRD.BKD |
Tolerance | The tolerance to which the minimum curvature surface must fit the data points before stopping (also see % pass tolerance). By default a tolerance of 0.1% of the data range is used. Script Parameter: UXGDRGRD.TOL |
% pass tolerance | When this percentage of data points has been fit within the tolerance, iterations cease. The default is 99%. Script Parameter: UXGDRGRD.PASTOL |
Max. iterations | The maximum number of iterations to enable in any iteration step. The default is 100 and should be increased only if the maximum iterations are exceeded and an acceptable solution has not yet been reached. Script Parameter: UXGDRGRD.ITRMAX |
Internal tension (0-1) | Overshoot of the valid data into voids can be reduced by increasing the internal tension of the fitted surface. The default is no tension (0). The tension can be increased to a maximum of 1.0. Script Parameter: UXGDRGRD.TENS |
Cells to extend beyond data | This is the number of grid cells to extend beyond the outside limits of the data. If the X and Y range values are not defined, the grid size will be set to the actual data range plus this value. At the present time, this operation also extends cells into interior regions without data, much like the blanking distance. For best results, use the blanking distance parameter to control the amount of coverage around data, and this parameter to set the default grid size, with this distance generally being smaller than the blanking distance to provide clipping around the grid. Script Parameter: UXGDRGRD.EDGCLP |
Display 1VD grid in | If the grids are to be displayed in a new map, an additional dialog will appear requesting the map name. Map layout, style and title settings may be defined using the MAP OPTIONS button. Pressing the button initializes a series of dialogs in which the map settings may be defined. Subsequent maps will default to the settings used. Script Parameter: UXGDRGRD.MAP |
Got a question? Visit the Seequent forums or Seequent support
© 2024 Seequent, The Bentley Subsurface Company
Privacy | Terms of Use