Full Level

Use the Full Level menu option (FULLEV GX) to adjust the values of an input channel by adding a correction defined in a error channel. The correction is linearly interpolated between defined values.

Level to Cross Lines dialog options

Channel to level

Input channel

Script Parameter: FULLLEV.IN

Cross-line error channel

Cross-line level error correction.

Script Parameter: FULLLEV.OUT

Output leveled channel

Output leveled Channel

Script Parameter: FULLLEV.ERROR

Apply to line types

The line types to be processed:

"Tie" to process tie lines only

"Line" to process lines only (default).

"Selected" to process currently selected lines

Script Parameter: FULLLEV.TYPE

Application Notes

The cross-line level error corrections can be extracted from an intersection table using the Load Corrections menu option. You can access this dialog by selecting the Load Corrections on the LevTieLine menu.

The ends of lines that extend beyond the last crossing line will be adjusted using the error at the last crossing. All other parts of the line are adjusted by assuming a linear error between crossing points.